beautypg.com

Operation, Finish operation maintenance and care – Karcher SCP 16000 IQ Level Sensor User Manual

Page 14

background image

Deutsch

7

The suction area should not be blocked
fully or partially through the impurities.

The liquid level must at least be 3 cm (SCP
16000) and 8 cm (SDP 18000) for the pump
to suck in liquids independently.
If the liquid level is less than 4 cm (only SCP
16000), proceed according to instructions
in the chapter of flat suction.
Î

Insert the plug in the socket and select
one of the following operating modes.

In the automatic mode, the level switch con-
trols the pumping operations. The pump
starts when the fluid level reaches the level
sensor. The pump switches off automatical-
ly after 10 to 60 seconds (depending on the
ambient conditions) when the fluid level
falls below the level sensor. The pump au-
tomatically conducts the adaptation to the
necessary trail time. Thi setting remains
saved for a max. of 24 hours or until the
mains plug is pulled out. If the mains plug is
pulled prior to the 24 hour time period, or af-
ter the 24 hours have elapsed, the pump
will automatically set the trail time to the set
value of 10 seconds.
The optimising of the trail time prevents fre-
quent switching on and off of the pump dur-
ing rapidly increasing water levels. In this
case, the pump will work even more effec-
tively, the higher the level sensor is in-
stalled.

In manual opertions the pump remains
switched on continuously.
Î

Set the switch at the level sensor to ON
position

Note:
Dry run leads to increased wear and tear;
do not leave the pump unattended when it
is running. Switch off the pump within 3
minutes of dry running
.

In flat suction mode, the fluids can be
sucked off up to 1 mm of residual height.
Î

Remove pre-filter

Î

Fold in the folding feet

Î

Set the switch for operating mode to ON
position

Î

When the remaining fluids have
reached a height of less than 10 mm,
press the dearation key or switch on/off
the pump many times by pressing the
mains switch till the fluid is sucked off.

Î

Rinse the pump with clean water after
use.
Especially after running chlorinated wa-
ter or other liquids that leave residue be-
hind.

Note
Contaminations can accumulate and lead
to malfunctions.
Î

Set the switch at the mains plug to OFF
position.

Î

Disconnect the main plug from the sock-
et.

Î

Clean the pre-filter with clean water.

The appliance is maintenance-free.
In order to ensure a reliable switching of the
pump, the level sensor should be cleaned
with a cloth (at least every 2 months).

Î

Store the appliance in a frost free area.

Operation

Automatic operation

Manual operation

Flat suction (only SCP 16000)

Finish operation

Maintenance and Care

Maintenance

Storage