BASIC TROuBLESHOOTING
CONNECTED mODELS ONLy
Failure Events and Safety Control
Appliance Does Not Turn On.
Check to ensure the steamer is plugged into
̆
the correct receptacle.
Check the branch circuit breaker to insure it
̆
is in the “ON” position.
The mechanical over flow level control has
̆
been removed. The steamer will not start
up until the mechanical level control is
reinstalled.
Call AccuTemp Products Technical Service
̆
Toll Free at 800 480-0415 or at 260 469-
3040.
No/Low Water Pressure or No/Low Flow of
Water into the Reservoir.
Check the supply water pressure
̆
Check for dirty inlet screen.
̆
Check for dirty probes.
̆
Call AccuTemp Products Technical Service
̆
Toll Free at 800.480.0415 or 260.469.3040.
Appliance Shuts Down During Operation.
Check conditions listed above for no/low
̆
water pressure or no/low flow of water into
the reservoir.
If the water level control valve is stuck “on”,
̆
the mechanical overflow level control will
shut down the whole Steamer and the water
supply by turning off the master water control
valve.
If the water level sensing control board
̆
becomes faulty, the mechanical over flow
level control will shut down the Steamer.
Call AccuTemp Products Technical Service
̆
Toll Free at 800 480-0415 or at 260 469-
3040.
Never leave a deliming agent in contact with
1.
the stainless steel longer than 10 minutes
before rinsing the cooking compartment
thoroughly with water. Longer contact can
cause corrosion.
Do not use abrasive materials, such as wire
2.
brushes, metal scouring pads or scrapers to
clean the cooking compartment bottom.
Service must be performed only by
3.
AccuTemp Products, Inc. Preferred service
agents. Service performed by non-preferred
service agents will void all warranties.
Any in-field modification made without
4.
written authorization from AccuTemp will
void the warranty.
WARNING