Vzn series, Installation – A.J. Antunes & Co VZN-440H 9700746 User Manual
Page 9
![background image](/manuals/432766/9/background.png)
VZN SERIES
9
P/N 1011064 Rev. F 12/13
INSTALLATION
Unpacking
1. Open the large box. It should contain:
A. Plate-mounted VZN system with Ultra Filter
Cartridge installed.
B. Padded envelope containing:
• Power Adaptor
• Adaptor Plugs
• Owner’s Manual
• Mounting Bracket
3. Remove all packing materials and protective coverings
from the system.
4. Remove the information packet. Fill out and mail the
warranty card immediately to prevent any delay in
obtaining warranty coverage.
NOTE: If any parts are damaged, contact A.J. Antunes &
Co. IMMEDIATELY at 1-800-253-2991 (toll free in the U.S.
and Canada) or 1-630-784-1000.
Equipment Setup
GENERAL
When placing the system into service, pay attention to the
following guidelines:
• Do NOT immerse cord or plug in water.
• Keep cord away from heated surfaces.
ELECTRICAL
The line voltage must match the voltage on the specification
label. The plug on the power cord must match the appropriate
outlet. Do NOT connect the system to a switched electrical
outlet.
PLUMBING
NOTE: The system must be connected to the COLD water
line. Do NOT connect the system to the hot water line.
The VZN system uses the following connections:
System Inlet
1" NPT
System Outlet
(Product Water)
1" NPT
Drain
3/4" FNPT
It is recommended that ball valves be installed on the inlet
and outlet of the system. This will aid in replacing cartridges
and servicing the system.
When making a plumbing connection to the system, use a
back-up wrench on the supporting plumbing. Always use a
quality, approved pipe sealant or thread seal tape on pipe
threads. Do NOT allow pipe sealant inside pipes.
Do NOT over tighten the connections. Use plastic fittings
when connecting to the plastic connections of the system.
If soldered plumbing is used, do NOT apply heat to, or near,
the filtration system. Use union (O-ring seal) connections for
ease of installation and future servicing.
SUGGESTED TOOLS AND SUPPLIES FOR INSTALLATION
The following tools and supplies are suggested to help with
the installation:
• Screwdriver
• Adjustable Wrenches
• Drill with Bits
• Level
• Tape Measure
• Pipe Dope or Thread Seal Tape
• Two Gallon Bucket
• Fresh, Unscented Liquid Chlorine
Bleach
• Pipe Wrenches
• Hose or pipe for drain line
• Ball Valves (for inlet, outlet, and
bypass)