Uf-216cc water filtration system, Installation (continued) – A.J. Antunes & Co UF-216CC 9700407 User Manual
Page 9
UF-216CC water Filtration system
9
A.J. Antunes & Co.
P/N 1011135 Rev. A 03/12
InstallatIOn (continued)
mounting the system
The UF-216CC system comes with a Mounting Bracket
to mount the system securely. When mounting the sys-
tem, pay attention to the following guidelines:
• Note the location of the water supply, drain, and
an appropriate electrical outlet when choosing a
mounting location.
• Allow sufficient access for cartridge replacement.
• Mount the system near but NOT above an appropri-
ate electrical outlet.
• Do NOT mount the system above any electrical
equipment or items that may be damaged if they
get wet.
• Mount the system near a drain for flushing opera-
tions.
• Mount the system before all consumable water
filtration processes.
• Secure the Mounting Bracket into wall studs or with
the appropriate heavy duty mounting hardware.
The system is pre-assembled to a Mounting Bracket.
The Mounting Bracket has mounting holes to secure
the bottom of the system to the wall.
Inlet water plumbing
The Inlet water plumbing line should be 1/2 ” NPT or
larger. A shutoff valve (not supplied) should be installed
in the line leading to the system. The valve should be
mounted close to the system inlet and sized properly for
the inlet plumbing line.
An optional “T” or Cross Fitting with cap or plug can be
installed between the Inlet Valve and the System Inlet.
This fitting can be used for draining and sanitizing the
system and downstream plumbing.
The system should only be connected to the cold water
line.
Before connecting the fitting to the System Inlet, the
plumbing to the system must be flushed clear of all
debris. Hold a bucket at the inlet water line and slowly
open the Inlet Water Valve. Allow the pipe to flush until
all debris is removed.