Uf-216cc water filtration system, Maintenance (continued), A.j. antunes & co – A.J. Antunes & Co UF-216CC 9700407 User Manual
Page 15
UF-216CC water Filtration system
15
A.J. Antunes & Co.
P/N 1011135 Rev. A 03/12
maIntenance (continued)
changing the Interval setting
resetting the timer program
During the normal operation, the system will flush
according to the set interval. It is possible the system
will flush at a time of high water use. If this poses a
problem, the controller can be reset. Unplug the power
supply, wait for 5 seconds, and then plug the power
supply in. When power is restored to the controller, it
will automatically enter Flush Mode. The controller will
then begin timing from the point when power is restored
based on the interval setting selected.
figure 7. controller
flush
Interval
button Hold time button
leD
flush
leD
15 minutes
A
10 seconds
On
On
30 minutes
B
10 seconds
On
On
45 minutes
C
10 seconds
On
On
1 hour
A
5 seconds
On
Off
4 hour
B
5 seconds
On
Off
6 hours
C
5 seconds
On
Off
12 hours
D
5 seconds
On
Off
24 hours
D
10 seconds
On
On
cautIOn
changing the flush interval can cause the ultra
filter to plug prematurely and may void the war-
ranty. consult the factory for more information.
Though not recommended, the Interval Setting on the
controller can be changed. If the setting must be
changed, use the chart below. Press and hold the cor-
responding button. After 5 seconds, the Button leD will
turn on. After 10 seconds, the Flush leD will also turn
on.