Ufl-410 water filtration system, Installation (continued), A.j. antunes & co – A.J. Antunes & Co UFL-410 9700459 User Manual
Page 14
UFL-410 WATER FILTRATION SYSTEM
14
A.J. Antunes & Co.
P/N 1011180 Rev. A 03/12
INSTALLATION (continued)
Sanitizing the System and Lines
The plumbing must be sanitized to eliminate possible
contamination that may have occurred during the instal-
lation process.
One ounce (30 ml) of liquid chlorine bleach (regular
bleach, unscented 6% sodium hypochlorite) can be
used to sanitize the plumbing. The amount of bleach
needed depends on the system and the amount of
plumbing downstream of the system.
NOTE: Follow the handling and safety instructions
supplied with the bleach.
1. Follow the steps in the
Rinsing the Ultra Filter
Cartridge in the Installation section of this manu-
al.
2. Turn off the water to the system.
3. Open the faucet or tap closest downstream to the
system.
4. Close the Inlet Water Valve and allow the system
to depressurize.
5. Place a bucket under the “T” or cross fitting at
the inlet connection to the system. Open the inlet
drain valve or unscrew the cap to drain the sys-
tem.
6. Press the
FLUSH button to help drain the system.
7. When the water flow out of the inlet fitting stops,
close the inlet drain valve and pour the liquid
bleach into the inlet connection fitting. Be careful
not to spill bleach onto clothing or skin. You may
want to add the bleach using a cup. Reattach the
cap on the fitting.
8. Slowly open the inlet water valve and allow water
to flow out of the tap until the smell of bleach is
present.
9. Immediately close the tap and let the system
stand with no water flow for at least 15 minutes to
allow the bleach to sanitize the pipes.
10. After 15 minutes without water flow, open the tap
and flush until the presence of bleach is gone. All
other taps should be opened to flush any bleach
from the plumbing. Close the taps.
11. Press the
FLUSH button to complete the flushing
process.
CAUTION
Ingesting the protective solution may cause irrita-
tion of the gastrointestinal tract, colic, diarrhea, or
other similar symptoms
IMPORTANT
Commonwealth of Massachusetts Plumbing Code
248 CMR shall be adhered to. The use of saddle
valves are not permitted, please consult your
local plumber.