Ufl-410 water filtration system, Installation (continued), A.j. antunes & co – A.J. Antunes & Co UFL-410 9700459 User Manual
Page 13
UFL-410 WATER FILTRATION SYSTEM
13
A.J. Antunes & Co.
P/N 1011180 Rev. A 03/12
INSTALLATION (continued)
Starting the Controller
1. Select the proper AC plug for your electrical outlet
and install it onto the power supply.
2. Plug the appropriate end of the power cord into
the controller.
3. Plug the other end of the power cord into the elec-
trical outlet. The LEDs on the controller will light
up.
4. The controller automatically enters Flush Mode
and the Flush LED starts to flash.
5. When flushing is complete, the Flush LED will
stop flashing and one or more LEDs will remain lit,
indicating the unit has power and which interval is
selected in the controller.
Rinsing the Ultra Filter Cartridge
The Ultra Filter Cartridge must be rinsed before the sys-
tem is used to remove any air and protective solution.
NOTE: Ultra Filter Cartridge must be rinsed to drain
before use. Rinsing to drain removes storage solu-
tion and air. Do NOT rinse into carbon if present.
Carbon life and/or performance may be affected.
1. Direct water from the Permeate Outlet to a drain.
2. Open the tap or faucet closest downstream to the
filter system.
3. Slowly open the inlet water valve and allow water
to enter the system.
4. Press the
FLUSH button. The Drain Valve will
open and air and water will come out of the drain
line. Repeat six times to ensure all air and stor-
age solution are flushed out of the Ultra Filter
Cartridge.
5. Allow water to continue to run through the system
and out the faucet for 15 minutes.
6. Inspect the unit for any leaks and repair as
needed.
7. After 15 minutes with water flow, close the tap or
faucet and let the system stand without water flow
for 15 minutes to allow trapped air to come out of
the hollow fibers of the Ultra Filter Cartridge.
8. After 15 minutes without water flow, open the tap
or faucet for five minutes to flush out the trapped
air.
9. Close the tap or faucet.
10. Press the
FLUSH button to open the Drain Valve.
Repeat six times to ensure any remaining air is
flushed out of the system.