UFC-420/440 water Filtration system

9

P/N 1010908 Rev. A 03/12

A.J. Antunes & Co.

The unit also must be flushed to remove air and the

shipping/storage solution. For maximum quality, the

permeate water produced during the flushing procedure

must be discarded. Direct this permeate water to drain.

1. Plug the power cord into the appropriate electri-

cal outlet. The display will power on and the LED

display will display the following for about two sec-

onds each:

8.8

F8 followed by its time settings in seconds

Fi and its time setting in minutes or hours.

The

F8 and Fi sequence repeats for 30 seconds

after which the unit automatically returns to the

Flush Interval Mode (Fi). The time setting for Fi will

be displayed and the decimal point will flash in one

second intervals.

2. open the tap or faucet closest downstream to the

filter system.

3. Slowly open the inlet water valve and allow water

to enter the system.

4. Press and hold the Start button. After 6-7 sec-

onds, the drain valve will open and FL will appear

on the display.

5. Continue holding the Start button down for at least

30 seconds to keep the drain open. This flushes

air out of the center of the hollow fibers. The

drain will remain open as long as the Start button

is pressed. Check to make sure that the drain

water is directed into the drain without splashing.

6. Release the Start button. This closes the drain

valve. Water should continue to flow through the

system and out of the open tap. Allow water to

flow out of the tap for at least 15 minutes at maxi-

mum flow rate.

7. Close the tap and let the system stand with no

water flow for 15 minutes to allow any trapped air

to come out of the hollow fibers. Check for leaks

at all fittings.

caUtIOn

Ingesting the protective solution may cause irrita-

tion of the gastrointestinal tract, colic, diarrhea, or

other similar symptoms

InstallatIOn (continued)

8. After 15 minutes without water flow, open the

tap for 5 minutes to allow any trapped air to be

flushed out.

9. Close the tap. Flushing is complete.

sanItIZInG tHe sYstem anD lInes

The plumbing must be sanitized to eliminate possible

contamination that may have occurred during the instal-

lation process. Chlorine bleach can be used to sanitize

the plumbing. The amount of bleach to use depends

on the system installed and the amount of plumbing

downstream of the filter system. Generally, 1 or 2

ounces (30 ml) of bleach will be sufficient to sanitize the

system.

1. Make sure that the system has been flushed of

air and debris as described in the Flushing and

Starting up the System section of this manual.

2. open the tap closest downstream to the filter sys-

tem.

3. Close the inlet water valve and allow the system

to depressurize.

4. Place a bucket under the strainer at the inlet

connection to the system. open the strainer by

unscrewing the cap. Water will flow out of the

strainer as the system drains.

5. When the water flow out of the strainer stops,

pour the liquid bleach into the strainer. Be careful

not to spill bleach onto clothing or skin. You may

want to add the bleach using a cup. Reattach the

cap on the strainer.

6. Slowly open the inlet water valve and allow water

to flow out of the tap until the smell of bleach is

present.

7. Close the tap and let the system stand with no

water flow for at least 15 minutes to allow the

bleach to sanitize the pipes.

8. After 15 minutes without flow, open the tap and

flush until the presence of bleach is gone. All

other taps should be opened to flush any bleach

from the plumbing.

9. Close the tap. The sanitization is complete.

Program the timer following the procedure outlined in

the operation section of this manual.