Operation (continued), A.j. antunes & co – A.J. Antunes & Co UFC-440 9700616 User Manual
Page 11
UFC-420/440 water Filtration system
11
P/N 1010908 Rev. A 03/12
A.J. Antunes & Co.
OperatIOn (continued)
programming timer
nOte: Once the Ufc unit is powered up, the
leD display cycles through the default or current
settings: flush Duration (fd) and its setting will
be followed by flush Interval (fi) and its settings.
at any time during this sequence, which lasts
approximately 30 seconds the UFC unit can be pro-
grammed.
setting the flush Interval (fI)
1. When Fi (Figure 5) is displayed, press and
release start button to view current setting .
2. To make a change, press and hold down start
button to scroll through settings - release button
at desired setting (Figure 6).
3. After ten seconds, unless start button is
depressed, unit automatically returns to
Flush Interval Mode.
nOte: fi times are displayed in ten minute inter-
vals, after fifty minutes they are displayed in hours
(table a).
figure 7. leD Display for flush Duration mode
figure 8. time setting fd mode (55 seconds)
table a. leD Display settings
figure 6. time setting fi mode (22 Hours)
figure 5. leD Display for flush Interval mode
setting flush Duration (fD)
2. When Fd is displayed, press and release start but-
ton to view current setting (Figure 7).
3. To make a change, press and hold down start
button to scroll through settings - release button
at desired setting (Figure 8).
4. After ten seconds, unless button is depressed,
unit automatically returns to Flush Interval Mode.
nOte:
fd
times are displayed in 5 second intervals
up to 60 seconds (table a).
1-
10 minutes
5
5 seconds
5- 50 Minutes
10
10 seconds
01 1 Hour
15
15 Seconds
12
12 Hours
30
30 Seconds
24 24 hours
60
60 Seconds
fi - flush Interval mode
fd - flush Duration mode