Uf series water filtration system, Operation, A.j. antunes & co – A.J. Antunes & Co UF-216 9700433 User Manual
Page 11
UF SERIES watER FIltRatIon SyStEm
11
A.J. Antunes & Co.
P/N 1010808 Rev. E 03/12
OperatIOn
figure 4. leD Display, front panel
starting the system
pOwer Up tHe UnIt.
The LED read-out displays the following for about two
seconds each:
1. 8.8
2. Fd followed by its time settings in seconds.
3. Fi and its time setting, in minutes or hours.
The
Fd and Fi sequence repeats for 30 seconds
after which, the unit automatically returns to the
Flush Interval Mode (Fi). The time setting for Fi
will be displayed and the decimal point will flash in
one second intervals.
nOte: the timer can be programmed immediately
after start-up or while in flush Interval mode.
filtration process
Water filtration in the UF Series is accomplished using
two modes:
• Flush Interval (Fi on the LED display)
• Flush Duration (Fd on LED display).
During the Flush Interval mode, water enters the inlet
and flows through the filter element before exiting the
Permeate outlet as usable product water. After a certain
period of time, depending upon water quality, the filter
has to be cleaned. This is accomplished through the
Flush Duration Mode. During this mode, the drain valve
opens and flushes the membrane to remove debris col-
lected inside the membrane walls.
nOte: both the flush Interval mode and the flush
Duration mode can be automated by programming
the timer. During the flush Interval mode, the valve
is not powered in order to keep water filtering during
a power outage.
leD Display
Fi - Flush Interval Mode is the time between flushings
and is displayed in minutes or hours.
Fd - Flush Duration Mode is the amount of time used
to flush and remove debris from filter cartridge and
is displayed in seconds.
FL - Manual Flush Mode operation, solenoid is
manually activated by the user.