VZN T5 SERIES
7
P/N 1011115 Rev. H 12/13
PERFORMANCE DATA SHEET
System has been tested according to NSF/ANSI Standard 42
and 53 for reduction of the substances listed below. The con-
centration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system, as specified
in NSF/ANSI 42 or 53. While testing was performed under
standard laboratory conditions, actual performance may vary.
Performance Claims for Percent Reduction
Substance
Influent
Challenge
Concentration
Reduction
Requirement
Minimum
%
Reduction
cyst
1
minimum
50,000/L
99.95%
99.95%
Turbidity
11 ± 1 NTU
≤ 0.5 NTU
99.1%
Particulate Class I
Particles 0.5 to <
1µm
at least 10,000
particles /mL
≥ 85%
N/A
1based on the use of microspheres or Cryptosporium parvum oocysts
NOTE: The NSF/WQA information provided applies to the
Ultra Filter cartridge.
Do not use with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before
or after the system. Systems certified for cyst reduction
may be used on disinfected waters that may contain fil-
terable cysts.
Filter Cartridge Capacities
Maximum Operating Pressure
100 psig (690 kPa)
Maximum Operating Temperature
100°F (38°C)
Minimum Operating Temperature
40°F (4°C)
Maximum Trans Membrane Pressure
45 PSI (3.1 Bar)
pH Range
3-10
MWCO
100 kD
NSF/WQA Certified Rated Service
Flow:
VZN-421HC-T5
7.9 gpm (30 l/m)
VZN-441HC-T5
13 gpm (49 l/m)
System Tested and Certified by NSF
International and WQA against NSF/ANSI
Standard 42 and 53 for the reduction of:
Standard No. 42: Aesthetic Effects
Nominal Particulate Reduction Class I
Standard No. 53: Health Effects
Cyst Reduction & Turbidity Reduction
as verified and substantiated by test data.
System Tested and Certified by WQA
against NSF/ANSI Standard 372
for lead-free compliance