Vzn t5 series, Specifications – A.J. Antunes & Co VZN-441HC-T5 9700773 User Manual
Page 6
![background image](/manuals/432754/6/background.png)
VZN T5 SERIES
6
P/N 1011115 Rev. H 12/13
SPECIFICATIONS
Dimensions
VZN-441HC-T5
VZN-421HC-T5
Replacement Cartridges
Replacement
Part Number
VZN-421HC-T5
L-420 Ultra Filter
7000411
VZN-441HC-T5
L-440 Ultra Filter
7000412
VZN-421HC-T5
VZN-441HC-T5
Chloramine Carbon
Element*
7000762
NOTE: Includes plug adaptors for US, Europe, Australia, and UK.
Model &
Mfg. No.
Width
(A)
Depth
(B)
Height
(C)
VZN-421HC-T5
9700771
31"
(79 cm)
9"
(23 cm)
39"
(99 cm)
VZN-441HC-T5
9700773
50"
(127 cm)
9"
(23 cm)
39"
(99 cm)
Electrical Ratings
Model &
Mfg. No.
Volts
Watts
Amps
Hertz
VZN-421HC-T5
9700771
100–240
10
.08
50/60
VZN-441HC-T5
9700773
100–240
10
.08
50/60
CAUTION
All electrical connections must be in accordance with
local electrical codes and any other applicable codes.
A ground fault circuit interrupter (GFCI) must be
installed on the circuit to this system.
When installed on metallic plumbing, a properly sized
electrical bonding jumper must be installed across the
inlet and outlet pipes serving this unit.
Electrical Cord & Plug Configurations
Kit Model
Number
Description
Configuration
0012146
DC Power Supply
100 - 240 VAC
Includes the
4 plug adaptors
below
NOTE: PLUG STYLE
MAY VARY
US
NEMA 1-15 (2 pin)
or NEMA 5-15
(3 Pin)
US
NEMA 1-15 (2 PIN)
or NEMA 5-15
(3 PIN)
Euro
CEE 7/16
EURO
CEE 7/16
AS/NZS
3112
AUS
(2 Pin)
AS/NZS 3112
(2 PIN)
AUS
UK
BS 1363
BS 1363
UK
UK
* Tested and verified by independent laboratory testing
A
C
B
A
C
B