Monthly maintenance – A.J. Antunes & Co MS-250 9100439 User Manual
Page 9
9
P/N 1010984 Rev. D 03/12
MonThly MainTenance
The Miracle Steamer utilizes an open steam
Generator. Water sprayed onto the Generator
surface flashes into steam immediately,
but the minerals in the water stay on the
Generator surface. A small amount of calcium/
mineral deposits are needed for proper opera-
tion, but a buildup of excessive calcium/min-
eral deposits causes poor steaming efficiency
and excessive moisture (wet steam), which
will eventually severely hinder the steaming
action.
CLEaNING StEaM GENErator
1. Turn the power off, unplug the power
cord, and allow the unit to cool down.
2. Perform the Daily cleaning, but do
NOT reassemble the unit.
3. Remove the Wing Nut, Generator
Cover, and Diffuser (Figure 8). Wash
these items in hot, soapy water, rinse
and wipe dry.
4. With the unit cool, use a wire brush
and/or scraper to loosen and remove
the excessive calcium/mineral deposits
from the Generator surface.
5. Take a wire brush and clean out any
buildup from the 28 Steam Ports
(26 vertical and 2 horizontal) of the
Generator (Figure 8). Remove the
loose buildup, wipe the Generator
with a clean, damp cloth, and reas-
semble the unit.
NotE: If deposits are still excessive and/
or difficult to remove, refer to Steps 6
and 11.
6. Pour delimer solution (not supplied)
onto the Generator surface. Follow the
delimer manufacturer’s instructions for
proper mixture and use.
WatEr taNK FILtEr (MS-150 oNLY)
The Water Tank Filter (Figure 9) is used to pre-
vent solids or food products from entering and
damaging the water pump. Inspect and clean
the Filter monthly or more regularly using the
following procedure:
NotE: the water level should be very low
or near empty.
1. Turn the power off, unplug the power
cord, and allow the unit to cool down
before proceeding.
2. Open the Tank Door (Figure 9).
3. Remove the Filter, located inside the
tank, by pulling it upwards and out of
the bottom hole.
4. Clean the Filter by running it under tap
water. Replace the Filter if the screen is
torn or damaged.
5. Reinstall the Filter Stem into the bot-
tom hole of the tank (Figure 9).
6. Fill the Water Tank, close the Tank Door,
and test the unit.
NotE: Do Not overfill the unit’s water
tank. only fill the tank to 90% full.
7. Using a sponge or a dry towel,
remove the delimer solution from the
Generator surface, then rinse with
clean water.
To ensure proper steaming characteristics,
some calcium/mineral deposits must be pres-
ent on the Generator surface. If, during clean-
ing, the surface does become free of calcium/
mineral deposits, add plain tap water to the
surface and allow it to boil off. If necessary,
repeat this process to formulate a thin coating
of calcium/mineral deposits.
CaUtIoN
If a chemical cleaner is used, be sure it is
safe to use on cast aluminum. Observe all
precautions and warnings on product label.
In soft water areas, it may be necessary to
add a small amount of lime to the Generator
to season it. This will ensure proper steaming
characteristics by producing a thin coating of
calcium/mineral deposits on the Generator
surface.
Seasoning mixture consists of 3/4 ounces
(25ml/ 25cc) baking soda, 3/4 ounces
(25ml/25cc) lime mixed with 1 quart
(950ml/950cc) of water. Stir mixture and pour
1/4” deep onto the hot Generator surface.
After mixture is converted to steam, the
remaining loose power can be removed.
8. Plug the power cord into the appropri-
ate outlet.
9. Turn the power on and allow the unit
to warm up for approximately 30
minutes.
10. Push and release the Operate button
or the Single Shot button several times
to operate the steamer. This purges any
remaining delimer residue from the
Generator surface.
11. Turn the power off, reinstall all parts
and accessories, and return the unit to
service.
READ
Y
Diffuser
Wing Nut
Generator
Cover
Figure 8. Monthly Cleaning
Generator
Steam ports
(26 vertical and
2 horizontal)
Figure 9. Water tank Filter
Water tank Filter
Filter Stem
access
Cover
with tank
(dotted line)
Bottom
Hole
of Water
tank
tank Door