ROTHENBERGER ROWELD D 4/15 Aero Basic User Manual
Page 28
26
ENGLISH
5.5
Set temperatures on temperature controller
Temperature chart:
Material Melttemperature Airtemperature
PP
200 – 240 °C
250 – 300 °C
PE
200 – 240 °C
250 – 300 °C
PVDF
240 – 260 °C
280 – 350° C
If other temperatures are needed, the corresponding settings can be made on the temperature
controller.
Set/operate temperature controller (1) - Function/description of LEDs
LED
GREEN
LED
RED
Operating mode
FLASHES
OFF
Heating element is being checked.
FLASHES
FLASHES
Temperature setting on temperature controller (1) is below the
minimum temperature, controller position approx. 20 (2). The
drive is blocked – cold start protection.
ON
FLASHES
Temperature setting on temperature controller (1) is above the
minimum temperature. On the minimum temperature being
reached, a timer is activated. Preheat time: 10 minutes.
ON
OFF
Ready for operation: timer has timed out,
drive has been released for operation.
OFF
FLASHES
Air failure: Allow machine to cool, pull mains connector, plug in
mains connector and heat up to just above the minimum tem-
perature, i.e. approx. position 30 (3).
On a renewed air failure, check the heating element and re-
place, if necessary.
OFF
ON
Current draw too high.
RESET by pressing the controller switch.
Check air temperature; if necessary, select a higher tempera-
ture and / or speed on the drive.
Guide values for air temperature / melt temperature
Check temperatures on the running extruder with an external thermometer after about 5
minutes.