ROTHENBERGER ROSOLAR PUMP/ROSOLAR PUMP PLUS User Manual
Page 16
12
ENGLISH
Material damage due to dry running!
Never allow the pump to run dry for more than 1 minute.
Material damage due to tilting of the cart on uneven ground!
Operate the filling unit only on even ground.
Danger of environmental damage due to hazardous pumped media!
Collect escaping pumped media and dispose of according to the locally applicable
regulations.
Material damage due to improper storage!
Prior to extended periods of pump down time clean pump to avoid adhesions and
damage to the impeller. Store pump under frost-protected conditions!
2
Technical Data
ROSOLAR PUMP
ROSOLAR PUMP PLUS
Voltage ...................................................... 230 V .............................. 230 V
Frequency ................................................. 50 Hz .............................. 50 Hz
Maximum power consumption ................... 750 W ............................. 370 W
Maximum fluid temperature ........................ 60°C ............................... 90°C
Approved pumping media ..........................
water, heat transfer medium
Maximum operating pressure ..................... 5,9 bar ............................ 5 bar
Maximum flow rate with
water / heat transfer medium .....................
35 / 31 l/min ....................
30 / 27 l/min
Diameter return hose / pressure hose ........ ½ / ½ inch ....................... ½ / ½ inch
Tank content .............................................. 30 l ................................. 30 l
Dimensions (height/width/depth) ................ 760 / 490 / 510 mm ........ 760 / 490 / 510 mm
Weight (empty tank) ................................... 23,3 kg ........................... 21,8 kg
Protection class ......................................... I ...................................... I
Protection type Motor ................................. IP 44 ............................... IP 55
Typical A-rated sound level:
Noise pressure level (L
pA
¦ K
pA
) .................. 72 dB (A) ¦ 3 dB (A) ...... 75 dB (A) ¦ 3 dB (A)
Sound power level (L
WA
¦ K
WA
) .................... 83 dB (A) ¦ 3 dB (A) ...... 86 dB (A) ¦ 3 dB (A)
The noise level during operation can exceed 85 dB (A). Wear hearing protection!
Measured values determined in accordance with EN 61029-1:2010.
3
Function of the Unit
3.1
Overview
(A)
1
Filling hose
5
Switch
2
Return hose
6
Ball valve
3
Tank
7
Tank lid
4
Pump outlet
8
Filter casing
3.2
Transportation and unpacking
After unpacking, immediately check the filling unit for completeness and damage.
Immediately report any transit damage to the supplying company.