Start of operation

Positioning:

Please pay attention to the position of the hexagon bolts (2)! Hexagon bolts must
not overlap the lower edge of the base plate!

Measure borehole and mark the centre. See technical data for extent of dowel depth!

Adjust and fasten base plate.

The respective optimum fastening possibility depends on the building site conditions (see
fastening possibilities, item 3.3)

Final fine adjustment or calibration of the drill stand by means of a circular level (7) in the handle.
The optimal result is achieved by tightening the four hexagon bolts (2).

Every time before start of operation make sure that the drill rig is firmly
fastened and not able to shake!

3.3

Fastening

possibilities

Dowel fastening on concrete or brickwork

Measure and drill a mounting hole for the dowel fastening. See technical data for extent

of dowel depth!

Diameter (mm)

Depth (mm)

Concrete (art. no. FF35120)

15

65

Brickwork (art. no. FF35121)

20

85

Carefully clean the drill dust from the borehole.

Apply the concrete dowel with expansion wedge or brickwork dowel (can be re-used up to 5
times)

Concrete set: Turn the diamond knurl threaded bar into the dowel, attach the drill rig and
fasten using the U-washer and nut.

Brickwork set: Screw the diamond knurl threaded bar with the grommet and mounted nut
into the armature. Tighten the nut using an open-ended spanner. Attach the drill rig and
fasten using the U-washer and nut.

Bracing with the quick clamp column (Item no. FF35015)

Align the drill rig and attach the quick clamp column to the base plate of the drill rig.

Extend the quick clamp column and clamp the drill rig.

Minimum room height:

approx. 1.7 m

Maximum room height:

approx. 3.0 m

Information: In order to avoid damage to the ceilings or walls by the quick clamp column,
place a piece of wood or similar between the end of the column and the ceiling to distribute

the contact pressure over a larger area.

Please read and be sure to understand the supplied quick clamp column instruction