beautypg.com

Installation, Positioning – Indesit FGIM-K-(BK)-S User Manual

Page 17

background image

GB

17

Installation

! Please keep this instruction booklet in a safe place for

future reference. If the appliance is sold, given away or

moved, please make sure the booklet is also passed on to

the new owners so that they may benefit from the advice

contained within it.

! Please read this instruction manual carefully: it contains

important information concerning the safe operation,

installation and maintenance of the appliance.

Positioning

! Do not let children play with the packaging material; it

should be disposed of in accordance with local separated

waste collection standards (see Precautions and tips).

! The appliance must be installed by a qualified professional in

accordance with the instructions provided. Incorrect installation

may damage property or cause harm to people or animals.

! This unit may be installed and used only in permanently

ventilated rooms in accordance with current National

Regulations. The following requirements must be observed:

• The room must be equipped with an air extraction system

that expels any combustion fumes. This may consist of

a hood or an electric fan that automatically starts each

time the appliance is switched on.

In a chimney stack or branched flue.

(exclusively for cooking appliances)

Directly to

the Outside

• The room must also allow proper air circulation, as air is

needed for combustion to occur normally. The flow of air

must not be less than 2 m

3

/h per kW of installed power.

The air circulation system may

take air directly from the outside

by means of a pipe with an inner

cross section of at least 100 cm

2

;

the opening must not be vulnerable

to any type of blockages.

The system can also provide the air

needed for combustion indirectly,

i.e. from adjacent rooms fitted with

air circulation tubes as described

above. However, these rooms must

not be communal rooms, bedrooms

or rooms that may present a fire

hazard.

• Liquid petroleum gas sinks to the floor as it is heavier

than air. Therefore, rooms containing LPG cylinders must

also be equipped with vents to allow gas to escape in

the event of a leak. As a result LPG cylinders, whether

A

Examples of
ventilation holes
for comburant air.

Enlarging the ventilation slot

between window and floor.

Adjacent

Room

Room to be

Vented

partially or completely full, must not be installed or stored

in rooms or storage areas that are below ground level

(cellars, etc.). It is advisable to keep only the cylinder

being used in the room, positioned so that it is not subject

to heat produced by external sources (ovens, fireplaces,

stoves, etc. ) which could raise the temperature of the

cylinder above 50°C.

Built-in appliances

Use an appropriate cabinet to ensure that the appliance

operates properly:

• the panels adjacent to the oven must be made of heat-

resistant material.

• cabinets with a veneer exterior must be assembled with

glues which can withstand temperatures of up to 100°C.

• to install the oven

under the counter (see diagram) or

in a

kitchen unit, the cabinet must have the following

dimensions:

595 mm.

595 mm.

25 mm.

545 mm.

5 mm.

567 mm.

23 mm.

575-585 mm.

45 mm.

558 mm.

547 mm. min.

! The appliance must not come into contact with electrical

parts once it has been installed.

The indications for consumption given on the data plate

have been calculated for this type of installation.

Ventilation

To ensure adequate ventilation, the back panel of the

cabinet must be removed. It is advisable to install the oven

so that it rests on two strips of wood, or on a completely

flat surface with an opening of at least 45 x 560 mm (see

diagrams).

560 mm

.

45 mm.

Centring and fixing

Secure the appliance to the cabinet by opening the oven door

and inserting 4 screws into the 4 holes on the outer frame.