Cleaning – Blodgett BLP-E Series User Manual
Page 15

OM-BLT/BLP-GE 13
Cleaning
11. Following supplier instructions, apply the sanitizing agent after the unit has
been cleaned and drained. Thoroughly drain off the sanitizer.
12. After the unit has been cleaned, sanitized and drained, let all surfaces air
dry unless the unit must be used again right away.
13. It is recommended that the unit be sanitized just before use. Follow the
directions of the sanitizer supplier.
14. About once a week (more often if the water is very hard), use a heavy
duty cleaner to remove any mineral deposits or film left by hard water or
foods. Follow the supplier’s directions very carefully, and rinse the unit off
thoroughly, as soon as cleaning is finished.
15. If especially difficult cleaning problems persist, contact your cleaning
product supplier for help. The supplier has a trained technical staff with
laboratory facilities to serve you.
CAUTION
NEVER LEAVE A CHLORINE SANITIZER IN
CONTACT WITH STAINLESS STEEL
SURFACES FOR LONGER THAN 30 MINUTES.
LONGER CONTACT CAN CAUSE CORROSION.
CAUTION
KEEP CAUSTIC COMPOUNDS SUCH AS
FRYER BOILOUT CLEANERS AWAY FROM
ALUMINUM PARTS OF THE LID HINGE
SYSTEM AND THE COUNTERBALANCE
ASSEMBLY. HIGHLY CAUSTIC COMPOUNDS
COULD DAMAGE THIS MATERIAL.