8 Troubleshooting

Fault

Cause

Remedy

‡ Motor does not start

> Fuse of the mains socket has

blown.

• Connect mains fuse.

> Overload protection switch

has tripped.

• Switch off the vacuum cleaner

and allow it to cool for approx.
5 minutes. If the cleaner
cannot be started again,
contact the Nilfisk-Alto service
department.

> Motor is faulty.

• Have motor changed by

Nilfisk-Alto Service.

Motor does not run in
automatic mode

*)

> Power tool/pneumatic tool is

defective or not connected
properly.

• Check that the power tool

works or that the plug is
inserted correctly.

> The power rating of the

electrical tool is too low.

• Note that minimum power

rating is P>40W

The acoustic warning
sounds. (Reduced suction
power)

> Suction power selected with

suction power control

*)

is too

low.

• Set suction power in

accordance with section
„Setting suction power“.

> Hose diameter does not

correspond with switch
position

• Set correct switch position for

hose diameter

> Clogged suction hose/nozzle. • Clean suction hose/nozzle
> Tank, disposal bag or filter

bag is full.

• See "Emptying tank" or

"Replacing disposal bag, filter
bag" sections.

> Filter element is clogged.

• See section „Cleaning filter

element“ and „Replacing filter
element“.

> Seal between tank and upper

section of vacuum cleaner is
faulty or missing.

• Replace seal.

> Cleaning mechanism is

defective.

• Contact Nilfisk-Alto Service.

No suction power during
wet cleaning

> Tank is full.

• Switch off the cleaner. Empty

the tank.

Voltage fluctuations

> Impedance of power supply is

too high.

• Connect the cleaner to another

socket closer to the fuse box.
Voltage

fluctuations

over

7% should not occur if the
impedance at the transfer point
is ≤ 0.15 Ω .