I N S TA L L AT I O N R E Q U I R E M E N T S
The model QC-3 is a counter mounted unit and
must be sealed to the counter with a NSF listed
silicone sealant.
For all other
models, install
the appliance
on a smooth and level floor
surface. Use the adjustable cabinet legs to level
the Quickchiller.
Adjust from front-to-back and from side-to-side
with the use of a spirit level to evenly distribute
the cabinet weight and avoid pulling the cabinet
alignment out of square.
After leveling the cabinet of cart equipped models,
check the height relationship of the roll-in cart to
the cabinet. Adjust the Quickchiller height as
needed to accommodate the cart and to securely
close the Quickchiller door(s).
D O O R S E A L :
Check the door gasket to make certain it is sealing
properly and that the gasket provides an even and
positive seal around the entire door frame.
WAT E R D R A I N A G E
A 1/2" I.D. (12,7mm) PVC pipe is furnished with
each QC-50 and QC-100 model. Use PVC glue to
attach the pipe into the drain opening at the rear
of the unit. Insert the PVC pipe into the drain
opening with a 1/4" (6mm) clockwise turn.
Connect the PVC pipe to discharge through an
indirect waste pipe into an open-site drain by
means of a 2" (51mm) air gap. Connection must
be within 10' (3m) of the unit.
NOTE:
In the U.S.A., this equipment is to be
installed to comply with the Basic
Plumbing Code of the Building Officials
and Code Administrators International,
Inc. [BOCA], and the Food Service
Sanitation Manual of the Food & Drug
Administration [FDA].
D R A I N A G E :
Q C - 3
Q C - 2 0
Q C - 4 0
EVAPORATOR PANS: NO INSTALLATION REQUIRED
Q C - 5 0
Q C - 1 0 0
ONE (1) FLOOR DRAIN:
1/ 2" (12,7mm) DIAMETER
DRAIN OPENING
AT REAR
C A U T I O N
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
I N S T A L L A T I O N
S I T E I N S T A L L A T I O N
Q U I C K C H I L L E R • I N S TA L L AT I O N / O P E R AT I O N / S E R V I C E M A N U A L • 4 .