Key Sequence Action

Addr Selects an active channel via keyboard.

Dnn Configures the dwell time. Substitute nn with

a value from 2 to 60 seconds.

SG Enables the scan Go command.

SH Enables the scan Halt command.

M+ Mouse will suspend scanning.

M- Mouse will not suspend scanning. (default)

MR If you hot-plug the SwitchView to a PC con-

nection you may experience a loss of mouse

signal. Use this command to restore the signal

if you’re using a PC with a standard PS/2

mouse driver. (See page 8)

MW Use this command to restore the mouse signal

if you’re using a PC with a Microsoft Intel-

liMouse driver. (See page 8)

Kn Sets keyboard scan set; n is a number 1 - 3.

AV Displays the current firmware version of the

SwitchView processors. You must be at a DOS

prompt or in a text editor/word processor to

view this information.

H1 Default Command Mode Activation

H2 Changes the Command mode activation

sequence to

H3 Changes the Command mode activation

sequence to

H4 Changes the Command mode activation

sequence to <->

ZM Used to resynchronize the mouse after a hot-

plug. Repeat, if necessary, until synchroniza-
tion is re-established.

NOTE: Using this command while the mouse

is operating correctly will cause the mouse
to lose sync.

Appendix

The following is a summary of all operational commands.