APW Wyott EHP User Manual
Page 7
WIRING DIAGRAM
INDICATOR
LIGHT
INDICATOR
LIGHT
REAR
ELEMENT
FRONT
ELEMENT
INFINITE
SWITCH
INFINITE
SWITCH
TERMINAL
BLOCK
X
Y
Z
1
2
4
10
10
7
8
12
12
9
9
6
5
R
R
11
11
L1
L1
L2
L2
H1
H1
H2
H2
3
1.
Wiring shown is for single phase. For three phase move wires #3 and #2 to the “Y” terminal on the
terminal block.
2.
On the SEHP units the #10 ground wire is omitted.
3.
For power supply use #10 AWG for both single and three phase.