Sc - set communications parameters – AT&T DEFINITY Remote Port Security Device User Manual
Page 73

SC - Set Communications Parameters
Syntax:
sc
[
RETURN
]
The Set Communications Parameters command is used to set the communications link speed,
character length, and parity on the serial port. The default setting is 9600 baud, 8 bit, no parity.
In the syntax above
sc
is the command,
speed
is the link speed, and
length_parity
are the
character length and parity.
The options for
speed
and
length_parity
are:
■
speed - 300, 600, 1200, 2400, 4800, 9600, or 19200 baud (trailing zeros may be omitted,
meaning you may enter
sc 24
for 2400 baud)
■
length_parity
➤
➤
➤
➤
8N - 8 bits no parity
7N - 7 bits no parity
7E - 7 bits even parity
7O - 7 bits odd parity
If either
speed
or
length_parity
are omitted, the current entry is left unchanged.
Sample Command and Response:
> sc 1200,7E
JPLock02 005 08/17/90 15:48:21 Comms Params Changed to 1200/7E
RPSD System Administrator Command Set