English - 63

07 TROUBLESHOO

TING

ERROR DISPLAY

TRIGGER

ACTION TAKEN

dF

Invalid door state for more than
256 milliseconds.

Call for service.

bE2

Invalid state of key circuit short for
30 secs

Make sure a button is NOT being pressed
continuously. Try restarting the cycle.
If the problem continue, call for service.

FE

Invalid power source Frequency

Try restarting the cycle.
If the problem continues, call for service.

2E

Electronic Control Problem
(Over Voltage Error)

Call for service.

AE

Electronic Control Problem
(Communication Error)

Call for service.

Et

Invalid state of Eeprom
communication

Call for service.

AE4

A communication error between the
Wi-Fi PBA and the MAIN PBA

Call customer service.

AE3

A communication error between the
DR Modem and the MAIN PBA

Call customer service.

AE5

A communication error between the
LCD PBA and the MAIN PBA

Call customer service.

For any codes not listed above, call 1-800-726-7864 (1-800-SAMSUNG)