beautypg.com

Mounting accessories included, Electrical connection (not for uk), Electrical connection for uk only – AEG DU 4561 User Manual

Page 19

background image

78

Mounting accessories included

3 screws 5 x 45 mm

3 wall plugs Ø 8 mm (brick fixing only)

4 screws 4,2 x 35 mm

1 screw 2,9 x 13 mm

1 flange Ø 125 mm

1 flange Ø 125/100 mm (DU 3150/3160/4161/4361/4561)

1 allen spanner (for TORX screws)

Electrical connection (not for UK)

Safety warnings for the electrician

Before connecting the appliance to the power supply, check that the

voltage indicated on the rating plate corresponds to the mains power

supply available. Appliances fitted with a plug can be connected to any

standard power socket within easy access.

Should it be necessary to provide a fixed connection, the hood must

only be installed by an electrician authorised by the local electricity

board. When installing, an omnipolar disconnector with a distance of at

least 3 mm between contacts must be provided.

Fixed connection of the appliance must only be carried out by an

authorised electrician.

Electrical connection for UK only

Safety warnings for the electrician

Connect the hood to the mains supply via a double pole switch

which has 3 mm minimum separation between the contacts.

The switch must be accessible at all times.

The following is valid in the United Kingdom only:

- the wire which is coloured blue must be connected to the terminal

which is marked with the letter N or coloured black, -

- the wire which is coloured brown must be connected to the terminal

which is marked with the letter L or coloured red.