4site master pm – Anritsu Site Master S331D User Manual
Page 10

Control Byte
#
Name
Description
Watchdog
Timer
42 (2Ah)
Power Meter Offset Mode
Enables or disables Power Meter offset
Yes
43 (2Bh)
Power Meter Zero Mode
Enables or disables Power Meter zeroing mode
Yes
44 (2Ch)
Power Meter RMS
Averaging On/Off
Sets Power Meter RMS Averaging.
Yes
45 (2Dh)
Power Meter Center
Frequency and Span
Sets the center frequency and span frequency for the Power Meter mode
Yes
48 (30h)
Trigger Sweep
Starts the next sweep
—-
50 (32h)
Check Battery Status
Returns smart battery status
—-
53 (35h)
Set SPA Minimum Sweep
Time
Sets the min sweep time for the SPA when the span is 0
Yes
54 (36h)
Set Trigger Position
Sets the trigger position for the SPA when the span is 0
Yes
55 (37h)
Set Video Trigger Level
Sets the trigger level for the SPA in video trigger mode
Yes
64 (40h)
Auto Save Runtime Setup
Automatically save the runtime setup when exiting remote mode
Yes
69 (45h)
Enter Remote Mode
Enters remote mode at the end of the sweep and returns model number and
firmware version
—-
70 (46h)
Enter Remote Mode
Immediately
Enters remote mode immediately and returns model number and firmware
version
—-
80 (50h)
Write Custom Cable
Writes Custom Cable data to Site Master
Yes
81 (51h)
Recall Custom Cable
Recalls Custom Cable data from Site Master
Yes
82 (52h)
Write Antenna
Writes custom antenna data to the Site Master via the serial port
Yes
83 (53h)
Recall Antenna
Recalls custom antenna data from the Site Master via the serial port
Yes
84 (54h)
Set Field Strength
Measurement
Sets the field strength measurement state and the antenna index
Yes
85 (55h)
Set Channel Power
Sets the Channel Power measurement state and the setup parameters
Yes
86 (56h)
Read Channel Power
Reads the current channel power or the channel power of a stored trace
Yes
87 (57h)
Set ACPR
Sets the ACPR measurement state and parameters
Yes
88 (58h)
Read ACPR
Reads the current adjacent channel power or the adjacent channel power of a
stored trace
Yes
89 (59h)
Read Signal Standard
Name
Returns the signal standard name in English
Yes
96 (60h)
Measure OCC BW % of
Power
Measures OCC BW with % of Power method
Yes
97 (61h)
Measure OCC BW dB
Down
Measures OCC BW with dB down method
Yes
98 (62h)
Set Bias Tee Function
Set the Bias Tee function On/Off (Option 10 only)
Yes
99 (63h)
Set Spectrum Analyzer
Start/Stop Frequency
Sets the Spectrum Analyzer Start and Stop frequencies
Yes
100 (64h)
Set Spectrum Analyzer
Center Freq./Span
Sets the Spectrum Analyzer center frequency and frequency span
Yes
101 (65h)
Set Spectrum Analyzer
Scale
Sets the Spectrum Analyzer reference level and scale value
Yes
102 (66h)
Set Spectrum Analyzer
Marker
Sets position and on/off status of a Spectrum Analyzer marker
Yes
103 (67h)
Set Spectrum Analyzer
Single Limit
Sets position and on/off status of Spectrum Analyzer single limit line
Yes
105 (69h)
Set Spectrum Analyzer Max
Hold
Enables or disables the Spectrum Analyzer Max Hold feature
Yes
4