NOTE: Regular maintenance is recommended to
keep the fryer operating properly.

Once each month, before beginning fryer opera-
tion, check the flue (behind the backsplash panel)
to ensure that it is clear, enabling exhaust combus-
tion gases to flow freely toward the ventilation
hood area. DO NOT allow the flue to become
excessively dirty. NEVER allow the flue to be
blocked.

Monthly, observe the condition of the ventilation
hood. If it shows evidence of a great deal of
greasy residue, remove (clean) the residue to allow
free flow of ventilation air.

MONTHLY MAINTENANCE INSTRUCTIONS

FR

FR

FR

FR

FRYER

YER

YER

YER

YER TR

TR

TR

TR

TROUBLESHOO

OUBLESHOO

OUBLESHOO

OUBLESHOO

OUBLESHOOTING GUIDE

TING GUIDE

TING GUIDE

TING GUIDE

TING GUIDE

PROBLEM

CAUSE

REMEDY

All service (repairs or part replacement) must be performed by a qualified Service Agency.

Pilot flame does not
stay lighted.

1. Dirty/sooty pilot burner.

2. Low gas supply pressure [less than 6”

W.C. for natural gas; (11” W.C. for pro-
pane) when all other gas-powered equip-
ment is operating].

3. Pilot flame too small to heat the thermo-

pile.

4. Pilot flame ‘wavering’ (being blown about

by a draft).

5. Improper thermopile output voltage

(must be at least 150 millivolts, measured
at the thermopile junction block).

1. Clean the pilot burner. Perform

the Lighting Procedure.

2. Measure the gas supply pres-

sure.
Contact your local gas supplier
to obtain adequate gas supply
pressure.

3. Adjust the pilot valve (part of

the gas control valve) to in-
crease the flame size: Un-
screw and retain the slotted
threaded cover; turn the pilot
valve adjustment screw two
turns
counterclockwise;
reinstall the threaded cover.

4. Block or redirect the draft, to

keep the flame burning steadily.

5. Replace the thermopile
.