Relative humidity chart, Setting the humidistat – AutoFlo S2020 User Manual
Page 4

10. SETTING THE HUMIDISTAT
Connect field wiring as shown in Figures 5 or 6.
It is recommended that humidistat settings of 30-40% not be 
exceeded. If condensation is noticed on windows during 
very cold outside temperatures, the humidistat setting should 
be lowered. 
4
RELATIVE HUMIDITY CHART
 Outside
Temperature
Outside
Relative
Humidity
Indoor Relative
Humidity
When Outside
Air Is Heated To
72 Degrees F
Maximum Safe
Recommended Indoor
Relative Humidity
-10 Deg. F
10 Deg. F
20 Deg. F
30 Deg. F
0 Deg. F
40%
40%
40%
40%
40%
60%
60%
60%
60%
60%
80%
80%
80%
80%
80%
1%
2%
2%
5%
8%
13%
2%
4%
6%
8%
2%
5%
7%
11%
17%
20%
25%
30%
35%
40%
FIG. 6
Furnace
S2000 & S2020 Humidifier
Humidistat
G1 R G2 H
H
Heat only
Thermostat
W
R
G
W
R
Heat Only System
The maximum recommended relative humidity for your 
home depends upon factors such as outdoor air temperature, 
type and placement of insulation, vapor barriers, 
effectiveness of weather stripping, type of windows and 
doors (including frames and jambs) and whether or not storm 
windows and doors are used. With all these variables it is 
nearly impossible to recommend a proper humidity setting. 
The best humidistat setting is one that you are comfortable 
with. Also, as the outdoor temperature fluctuates, it may be 
necessary to adjust the humidity level of your system a few 
times during the heating season.
Refer to the "Relative Humidity Chart" as a starting point for 
your proper humidistat setting. Generally, in a tighter and 
better insulated house, the humidistat may be set higher than 
in a drafty, un-insulated house. 
IMPORTANT: If the humidifier is installed in the return air 
plenum the humidistat must be located at least three (3) feet 
upstream from the humidifier. Fan should be operated in 
continuos mode when humidistat is mounted in the return air 
plenum.
The humidistat has two (2) screw terminals which should be 
connected to the low-voltage interlock plug. (Figure 5). 
Wiring instructions for the 072000 model Humidistat are 
packaged with the 072000.