4. Optional Charger Single-LED Display (internal or external)
LED Colour
Indication (following “Power-On Self Test”)
Green
Solid:
Charging complete. Charger in Maintenance Mode.
Flashing:
Short: <80% Charge.
Long: >80% Charge.
When battery is not connected: Algorithm Number
display.
Amber
Flashing:
Reduced Power Mode: Low AC Voltage or High
internal charger temperature.
Red
Flashing:
Charger error. Reset charger power and refer to
Troubleshooting Instructions below.
Maintenance Instructions
-
1. Do not expose charger to oil, dirt, mud or direct heavy water spray when cleaning vehicle.
2. If the detachable input power supply cord set is damaged, replace with a cord that is:
a.) for North America - UL or CSA listed/approved detachable cord, 3 conductor, 16AWG minimum, and rated SJT;
terminating in a grounding type IEC 60320 C14 plug rated 250V, 13A minimum; or
b.) for all other countries – a safety approved detachable cord, 3 conductor, 1.5mm² minimum, rated appropriately for
industrial use. The cord set must be terminated on one end with a grounding type input connector appropriate for
use in the country of destination and, on the other end, an output grounding type IEC 60320 C14 plug.
3. The enclosure of the charger has been tested successfully to EN60529, meeting IP66. The AC supply inlet is rated to
IP20, which is suitable for indoor use only. Keep all AC connections clean and dry.
Troubleshooting Instructions
-
If a fault occurs, count the number of red flashes between pauses and refer to the table below:
Red Flashes
Cause
Solution
Battery High Voltage
Check battery size and condition and reset charger
(interrupt AC power for 15 seconds).
Battery Low Voltage
Check battery size and condition and reset charger
(interrupt AC power for 15 seconds).
Charge Timeout caused by
battery pack not reaching required
voltage. Charger output was
reduced due to high temperatures
Check connections.
Operate charger at a lower ambient temperature.
Check Battery: battery could not
be trickle charged up to minimum
voltage
Check for shorted or damaged cells.
Over-Temperature: Charger shut
down due to high internal
temperature.
Ensure sufficient cooling air flow and reset charger
(interrupt AC power for 15 seconds).
Charger Internal Fault
Reset charger (interrupt AC power for 15 seconds).
Return to qualified service depot if fault persists.