Electric Vehicle

Battery Charger

• Advanced high frequency design with > 90% efficiency and >.99 power factor
• Wide range AC input (85 - 265 VAC) for worldwide operation
• Fully sealed enclosure provides improved reliability in demanding environments
• Approved battery charge algorithms for ideal charging
• Integrated Charge Tracking for Advanced Troubleshooting and Charge History Analysis

subject to change without notice

720-0001 R

ev 5 October 7, 2011

QuiQ HF/PFC Battery Charger Specifications

QuiQ and the Power in Motion slogan are

trademarks of Delta-Q Technologies Corp.

Copyright © 2006 Delta-Q Technologies Corp.

QuiQ Model: 912- or 913-

24xx 36xx 48xx 72xx 84xx 96xx

DC Output

DC Output Voltage - nominal

24 V 36 V 48 V 72 V 84 V 96 V

DC Output Voltage - maximum

34 V 51 V 68 V 100 V 120 V 135 V

DC Output Current - maximum

25 A

21 A

18 A

12 A

10 A

9 A

DC Output Power - maximum

695 W 875 W 1000 W 1000 W 1000 W 1000 W

Interlock Current - maximum

1 A

1 A

1 A 0.5 A 0.5 A 0.5 A

Battery Type

Specific to selected algorithm

Reverse Polarity

Electronic protection – auto-reset

Short Circuit

Electronic current limit

AC Input

AC Input Voltage - range

85 - 265 VAC

AC Input Voltage - nominal

120 VAC / 230 VAC rms

AC Input Frequency

45 - 65 Hz

AC Input Current - maximum/nominal 12 A / 9.5 A rms @ 120 VAC or 5 A rms @ 230 VAC
AC Power Factor - nominal

> 0.99 @ 120 VAC / > 0.98 @ 230 VAC

Mechanical

Dimensions

28.0 x 24.6 x 11.0 cm (11 x 9.7 x 4.3”)

Weight

< 5 kg (< 11 lbs) w/standard output cord

AC input connector

IEC320/C14 (require ≥ 1.8m localized cord)

DC output connector

OEM specific w/12AWG wire

Environmental

Enclosure

IP66 (NEMA4)

Operating Temperature

-30°C to +50°C (-22°F to 122°F), derated

above 30°C (86°F), below 0°C (32°F)

Storage Temperature

-40°C to +70°C (-40°F to 158°F)

Regulatory

Safety

UL approved to UL1564 3rd Ed., and CSA 107.2,

EN 60335-2-29, Designed to meet UL2202 1st Ed.

Emissions

FCC Part 15/ICES 003 Class A, EN 55011,

EN 61000-3-2, EN 61000-3-3

Immunity

EN 61000-4-2/-3/-4/-5/-6/-11

Operation

AC ON

Solid YELLOW AC LED

>80% Charge Indicator

Solid YELLOW Charge LED

100% Charge Indicator

Solid GREEN Finish LED

Fault Indicator

Flash RED Fault LED

DC Ammeter

LED Bargraph (6 level)

Long-term Storage Mode

Auto-restart if battery voltage < 2.1 V/cell or 30 days elapse

Special Features

Battery Temperature Monitoring with Multiple Temperature Sensor Options
External Communications

PC-based configuration software for field programmability
Advanced Microprocessor with Integrated Charge Cycle and Event Tracking

Options

• OEM Specific DC Output Cord
• Localized AC Input Cord
• Reverse or Dry Contact Interlocks
• Handle

Rear view of QuiQ ICON configuration shows inline DC and signal

connectors (charger output on left, signal I/O on right).

Mate with OEM specific output cords.

HF/PFC Battery Chargers

246

mm

9.7"

260 mm

10.2"

125

mm

4.9"

278 mm

10.9"

This manual is related to the following products: