Components, Electrical, Table 7 troubleshooting chart, cont’d – Wesley SCT-7750-8AC User Manual
Page 32
![background image](/manuals/416180/32/background.png)
Owner’s Manual and Service Guide – SC & SCT Series
32
COMPONENTS
-
ELECTRICAL
Fault Codes and Troubleshooting Chart:
Table 7 TROUBLESHOOTING CHART, cont’d
LED
CODE
PROGRAMMER
LCD DISPLAY
FAULT
CATEGORY
POSSIBLE
CAUSE
FAULT CLEARANCE
4,1
LOW BATTERY VOLTAGE
2
1. Battery voltage < undervoltage cutback.
2. Corroded battery terminal.
3. Loose battery or controller terminal.
When voltage rises above
undervoltage cutoff point.
4,2
OVERVOLTAGE
2
1. Battery voltage > overvoltage shutdown
limit.
2. Vehicle operating with charger attached.
When voltage falls below
overvoltage cutoff point.
4,3
THERMAL CUTBACK
2
1. Temperature > 85°C or < -25°C.
2. Excessive load on vehicle.
3. Improper mounting of controller.
Clears when heatsink
temperature returns to
within acceptable range.
4,4
ANTI-TIEDOWN
3
1. Made switches shorted to B+.
2. Made Select 1
“tied down” to select Mode 2
or Mode 4 permanently.
Release Mode Select 1.
MOTOR HOT
3
1. Field resistance > motor hot setpoint.
When resistance < setpoint.
MOTOR WARM
3
1. Field resistance > motor warm setpoint.
When resistance < setpoint.