3 setup loggernet – Campbell Scientific Redwing100 CDMA Cellular Digital Modem User Manual
Page 7

Redwing 100 AirLink CDMA Modem
3
5. Enter the MDN.
6. Enter the MIN.
7. Press the “Start” button to program the phone.
3.3 Setup LoggerNet
1. Select Add Root | TapiPort.
2. Add a TapiRemote to the TapiPort.
3. Add a datalogger to the TapiRemote.
4. On the TapiPort page, select your installed modem on the Tapi Line.
5. On the TapiRemote un-check “Use Tapi Dialing Properties.“
6. Enter the phone number of the CDMA phone.
7. Apply the changes and test.
If you have a black SC12 cable, that is not Rev 1 or newer, it is a
CS I/O cable only and will not work for RS-232. Connect the
black SC12 cable between the datalogger and the SC932A. Use
a 9-pin serial cable or a blue ribbon cable between the phone and
the SC932A.
NOTE