CS115 Barometric Pressure Sensor
10
3: Period Average (SE) (P27)
1:
1
Reps
2:
14
200 kHz Max Freq @ 500 mV Peak to Peak, Freq Output
3:
24*
SE Channel
4:
10
No. of Cycles
5:
5
Timeout (units = 0.01 seconds)
6:
1*
Loc [ P_mb ]
7:
1000
Mult
8:
0.0
Offset
;Turn off CS115
;
4: Do (P86)
1:
51*
Set Port 1* Low
5: End (P95)
6: If time is (P92)
1:
0
Minutes (Seconds --) into a
2:
60
Interval (same units as above)
3:
10
Set Output Flag High (Flag 0)
7: Real Time (P77)
1:
0110
Day,Hour/Minute (midnight = 0000)
8: Sample (P70)
1:
1
Reps
2:
1*
Loc [ P_mb ]
*Table 2 Program
02: 0.0000
Execution Interval (seconds)
*Table 3 Subroutines
End Program
-Input Locations-
1 P_mb 1 1 1
* Proper entries will vary with program and datalogger channel, and input location assignments.