CS115 Barometric Pressure Sensor
8
8: Sample (P70)
1:
1
Reps
2:
1*
Loc [ P_mb ]
*Table 2 Program
02: 0.0000
Execution Interval (seconds)
*Table 3 Subroutines
End Program
-Input Locations-
1 P_mb
* Proper entries will vary with program and datalogger channel, and input location assignments.
5.1.2 Period Averaging Measurement Example for CR10(X) in a Slow
Executing Program
EXAMPLE 2. Sample Program for CR10(X)
;{CR10X}
;
*Table 1 Program
01: 10
Execution Interval (seconds)
;Turn on CS115
;
1: Do (P86)
1:
48*
Set Port 8* High
;Give 2 second delay for CS115 to settle
;
2: Excitation with Delay (P22)
1:
1
Ex Channel
2:
0
Delay W/Ex (0.01 sec units)
3:
200
Delay After Ex (0.01 sec units)
4:
0
mV Excitation
3: Period Average (SE) (P27)
1:
1
Reps
2:
14
200 kHz Max Freq @ 2 V Peak to Peak, Freq Output
3:
6*
SE Channel
4:
10
No. of Cycles
5:
5
Timeout (units = 0.01 seconds)
6:
1*
Loc [ P_mb ]
7:
1000
Mult
8:
0.0
Offset