beautypg.com

Samlex America PST-200S-24E User Manual

Page 23

background image

22 | SAMLEX AMERICA INC.

SAMLEX AMERICA INC. | 23

seCtIOn 7 |

General Information on Batteries for

Powering Inverters

based on the actual application requirements.

Please consider using the following Programmable Low Battery Cut-off / “Battery
Guard” Models manufactured by Samlex America, Inc. www.samlexamerica.com

- BG-40 (40A) – for up to 400W, 12V inverter or 800W , 24V inverter

- BG-60 (60A) - for up to 600W, 12V inverter or 1200W , 24V inverter

- BG-200 (200A) - for up to 2000W, 12V inverter or 4000W , 24V inverter

Depth of Discharge of Battery and Battery Life

The more deeply a battery is discharged on each cycle, the shorter the battery life. Using
more batteries than the minimum required will result in longer life for the battery bank.
A typical cycle life chart is given in the Table 7.5 below:

tABLe 7.5: tYPicAL cYcLe LiFe cHARt

Depth of Discharge

% of Ah capacity

cycle Life of Group

27 /31

cycle Life of Group

8D

cycle Life of Group

Gc2

10

1000

1500

3800

50

320

480

1100

80

200

300

675

100

150

225

550

note: It is recommended that the depth of discharge should be limited to 50%.

Series and Parallel connection of Batteries

Series connection

Fig 7.2: Series Connection

When two or more batteries are connected in series, their voltages add up but their
Ah capacity remains the same. fig. 7.2 above shows 4 pieces of 6V, 200 Ah batteries
connected in series to form a battery bank of 24V with a capacity of 200 Ah. The Posi-
tive terminal of Battery 4 becomes the Positive terminal of the 24V bank. The Negative

6V

6V

Battery 4

Battery 3

6V

Battery 2

6V

Battery 1

24V Inverter

or 24V Charger

Cable “A”

Cable “B”

This manual is related to the following products: