beautypg.com

Samlex America SEC-1223 User Manual

Page 6

background image

!

BATTERY CHARGING AND BATTERY BACK-UP

WARNING ! THESE UNITS ARE POWER SUPPLIES AND

NOT BATTERY CHARGERS. DO NOT CONNECT THESE UNITS DI-
RECTLY TO A BATTERY

These units should NOT BE DIRECTLY CONNECTED TO A BATTERY
for charging or for battery back-up. Battery charging and battery back-up
may be undertaken only when the battery is connected through suitable
external isolating diodes and charge limiting resistor. The isolating diode
will ensure that the battery does not back power the power supply. When
a battery is deeply discharged, it will initially draw a very large charging
current and thus, will force the power supply into current limit mode for
prolonged periods. This is harmful for the power supply. The charge
limiting resistor will limit the charging current, thereby, ensuring that the
maximum charging current is well below the current limit value of the
power supply. It is recommended that optional battery back-up
module BBM-1225 may be used to convert SEC-1212/SEC-1223 for
battery back-up application.

TROUBLESHOOTING - GENERAL

PROBLEM : Power ON/OFF switch does not illuminate when turned on.

PROBABLE CAUSE

SUGGESTED REMEDY

No power in the AC outlet

Check there is power in the outlet.

AC side fuse inside the power

Replace the fuse inside the unit.

supply is blown

See fuse ratings at page 11

PROBLEM : AC side fuse blows as soon as power is turned on.

PROBABLE CAUSE

SUGGESTED REMEDY

Unit is defective

Call technical support.

5.