SPECIFICATIONS

INPUT VOLTAGE(nominal)

120 VAC, 60 HZ

OUTPUT VOLTAGE

13.8 VDC

OUTPUT RIPPLE & NOISE (On Full Load)

150 mV PEAK TO PEAK

OUPUT CURRENT, CONTINUOUS

SEC-1212

10 A

SEC-1223

23A

CURRENT LIMIT

SEC-1212

14A

SEC-1223

25A

COOLING

SEC-1212 - CONVECTION COOLED
SEC-1223 - TEMPERATURE CONTROLLED FAN

PROTECTIONS

OVER CURRENT, SHORT CIRCUIT AND
OVER VOLTAGE (Through PWM Controller)
OVER TEMPERATURE SHUT DOWN (SEC-1223)

ENVIRONMENTAL TEMP. RANGE

SEC-1223

0 - 40

o

C

SEC-1212

0 - 30

o

C

CONNECTIONS

AC INPUT:

DETACHABLE POWER CORD C/W NEMA 5-15P PLUG

DC INPUT:

TERMINALS WITH TUBULAR HOLE DIA. 0.2” (5mm)
WITH SET SCREW

FUSE RATING

5 MM X 20 MM GLASS FUSE, 125V or 250 V
(Time Delay / Slow Blow)

Bussmann

Littelfuse

SEC-1212 - 3A

GDC-3

239003

SEC-1223 - 6.3 A

GDC-6.3

21806.3

DIMENSIONS ( W X D X H ), INCHES

7.0 X 8.25 X 2.2

WEIGHT

SEC-1212

3 LBS. NET

SEC-1223

3.5 LBS. NET

SAFETY CERTIFICATION

UL60950-1, E179076

EMC CONFORMITY

FCC Part 15(B), Class B Digital Device

NOTE: SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE