beautypg.com

Avanti ELECRIC RANGE ER2001G User Manual

Page 14

background image

14

Screws

Terminal Block
Access Plate

Bracket

Power Cord

Power Wires

Neutral Wire

Cut Ground Strap

Terminal Block

Grounding Screw

Grounding Wire

Bracket

Power Cord

Power Wires

Neutral Wire

Terminal Block

Cut Ground Strap

3-Wire Power Cord Installation
• Remove the Terminal Block Access Plate on the back

of range by removing the 2 fixing screws.

• Assemble the strain relief in the hole on bracket.
• Insert the power cord through the strain relief and

tighten.

• Allow enough slack to easily attach the cord terminals

to the terminal block.

• Remove the 3 wire terminal nuts and washers from

the terminal block.

• Plug the terminal holes of power cord. The neutral or

ground wire of the power cord must be connected to
the neutral terminal located in the center of terminal
block. The power leads must be connected to the
outside terminals.

• Plug washers and tighten nuts securely.
• Assemble the Terminal Block Access Plate.



Grounding Screw

Grounding Wire

Bracket

Power Cord

Power Wires

Neutral Wire

Terminal Block

Cut Ground Strap



4-Wire Power Cord Installation
• Remove the Terminal Block Access Plate on the back

of range by removing the 2 fixing screws.

• Assemble the strain relief in the hole on bracket.
• Insert the power cord through the strain relief and

tighten.

• Allow enough slack to easily attach the cord terminals

to the terminal block.

• Remove the 3 wire terminal nuts and washers from

the terminal block.

• Remove the ground strap from the frame of range and

terminal by removing its screw and cutting is as
shown.

• Plug the terminal holes of power cord. The neutral wire of the power cord must be connected to

the neutral terminal located in the center of terminal block. The ground wire of the power supply
cord must be attached to the frame of range by using the green colored grounding screw. The
power leads must be connected to the outside terminals.

• Plug washers and tighten nuts securely.
• Assemble the Terminal Block Access Plate.

The range must be level to obtain proper operating. The four screws
type leveling legs located on the corners at the bottom of range should
be adjusted by turning them clockwise to make the range higher or
counter-clockwise to lower the range until the range is level. Use a
level on surface units to check the leveling of the range.

LEVELING THE RANGE