beautypg.com

Items supplied/dimensions, Wall mounting, Screwing on the connection pipes – Siemens DO10702 User Manual

Page 3: Putting into operation, Replacing the power supply cord

background image

Dispose of the packaging and old unit, if necessary, in an
environmental friendly manner.

S a f e t y I n f o r m a t i o n

Have the small water heater connected only by
a specialist.

Observe the legal regulations as well as the connection
conditions of the electrical power company and the water
works.

Caution!
Fill the unit completely with water first and then plug in
the mains plug. Otherwise, the resettable safety
temperature limiter will trip.

Connect the unit only to a mains socket with protective
contact that is installed according to regulations. Do not use
an extension cord. If necessary, equip the unit with a longer
cord (see Section F).

The small water heater may be used only open
(unpressurised) and for one tapping point. The warm
water outlet serves for pressure equalisation and
may be connected only to the mixing battery provided
(Order No. BZ 13050 for units without battery).

The outlet of the battery must always be free.
Do not use a aerator (air mixer).
During heating, expansion water drips from the outlet.

The supply cord should not touch hot parts. The insulation
could be damaged.

The unit is to be mounted only in frost-free rooms.

After mounting, please give the instructions for use to
the owner and explain the unit to him.

Maintenance and repair work should only be performed
by a qualified professional.

Disconnect the power supply before opening the

appliance.

Items Supplied/Dimensions

On DO 05702, DO 05752, DO 3170D and DO 3175D, detach
the mounting bracket by bending it up several times.

M o u n t i n g

Water Connection

Caution!
Do not allow the existing mixing battery to become
calcified. A reduced flow rate will ruin the water heater.

Wall Mounting

For mounting without the wall hooks, observe the different
dimensions!

Screwing on the Connection
Pipes

Observe the correct sequence: Slide the sleeve nut 1,
washer 2 and seal 3 onto the connection pipe.

Insert the pipes vertically and without tension to the stop.

Place the sleeve nuts onto the threads and screw on by
hand.

Tighten the crimp fittings. Hold the threaded fittings on the
water heater with a spanner. Do not lubricate the thread!

Retighten the crimp fittings after a few heating cycles.

Replacement for a damaged threaded fitting is available
from customer service.

Putting into Operation

1. Open the angle valve. The mains plug must not be

plugged in.

2. Completely fill the heater’s reservoir with water.

Set the flow on the angle valve

5-Litre unit:

5 l/min = 1 l in 12 seconds

10-Litre unit:

10 l/min = 1 l in 6 seconds

3. Only after steps 1 and 2 have been completed:

Insert the mains plug.

Turn the temperature selector to “III” (approx. 85° C).

Observe the heating until the control lamp goes off.

Heating time:

5-litre unit:

12–18 minutes

10-litre unit:

25–35 minutes

Check the temperature.

Caution: if the safety temperature limiter has switched off
the small water heater, disconnect the mains plug, open the
hot water tap, allow approx. 4 litres of water to run through
and then reconnect the mains plug. The unit is now ready
for operation again.

4. Limiting of the Outlet Temperature

The outlet temperature of the water heater can be
mechanically limited to Step I (approx. 40 °C) or
Step e (approx. 60 °C).

Information on temperature limiting can be found in
the instructions for use.

Replacing the Power Supply
Cord

The power supply cord must be replaced by our
customer service only in order to avoid a hazard.

The mains plug must be pulled before replacing.

3

en

E

B

C

D

F

A