8.7 Fan and GPO Commands

Table 31: Fan and GPO Commands

Command

Syntax

Default

Notes

General purpose output off

FE 56

254 86

254 “V”

Off

This

command

turns OFF any

of the General

Purpose Outputs.

[gpo#] is 1 to 6.

General purpose output on

FE 57

254 87

254 “W”

Off

This

command

turns ON any

of the General

Purpose Outputs.

[gpo#] is 1 to 6.

PWM value

FE C0

254 192

0

This

command

sets one of the

high power GPOs

(GPOs 1-3) into

PWM mode.

Return fan RPM

FE C1

254 193

n/a

This

command

will

return

a

packet to the host

with the fan RPM

contained in it.

Remember GPO / PWM

state

FE C3

254 195

n/a

This

command

will set the startup

state for all the

GPOs.

Set PWM base frequency

(New in Firmware Revi-

sion 2.1)

FE C4 [index]

254 196 [index]

6

This

command

sets

the

base

frequency for the

PWM

modula-

tion.

Remember PWM base fre-

quency

(New in Firmware Revi-

sion 2.1)

FE C5 [index]

254 197 [index]

6

This

command

will set the PWM

frequency

for

startup.

Matrix Orbital

PK202-24-USB