11.4

Set and Save Data Lock

Syntax

Hexadecimal

0xFE 0xCB 0xF5 0xA0 [level]

Decimal

254 203 245 160 [level]

Parameters

Parameter

Length

Description

level

1

Sets the data lock level

Description

This command will set and save the data lock level. See the Data Lock
section for more information.

Remembered

Always

Default

0

11.5

Write Customer Data

Syntax

Hexadecimal

0xFE 0x34 [data]

Decimal

254 52 [data]

ASCII

254 “4” [data]

Parameters

Parameter

Length

Description

data

16

Writes the customer data

Description

Writes the customer Data. 16 Bytes of data can be saved in non-volatile
memory.

Remembered

No

11.6

Read Customer Data

Syntax

Hexadecimal

0xFE 0x35

Decimal

254 53

ASCII

254 “5”

Description

Reads whatever was written by Write Customer Data.

Remembered

No

12

Miscellaneous

12.1

Introduction

This chapter covers the ’Report Version Number’ and ’Read Module Type’ commands. These commands

can be particularly useful to find out more information about the display module before contacting technical
support.

Matrix Orbital