beautypg.com

General purpose output – Matrix Orbital LK204-25 User Manual

Page 29

background image

29

4. General Purpose Output

4.1. General Purpose

Output Off

Dec
Hex
ASCII

254 86

FE 56

■ V

Number
Number
Number

Turns the specified GPO off, sinking current to an output of zero volts.

Number

1 byte, GPO to be turned off, value between 1 and 6


4.2. General Purpose

Output On

Dec
Hex
ASCII

254 87

FE 57

■ W

Number
Number
Number

Turns the specified GPO on, sourcing current from an output of five volts.

Number

1 byte, GPO to be turned on, value between 1 and 6


4.3. Set Start Up

GPO State

Dec
Hex

254 195

FE C3

Number State
Number State

Sets and saves the start up state of the specified GPO in non volatile memory. Changes will be seen on start up.

Number

1 byte, GPO to be controlled, value between 1 and 6

State

1 byte, 1 for on or 0 for off