Matrix Orbital LK162-12 Legacy User Manual
Page 38

LK162-12 rev 4
38
Command
Syntax
Default
Notes
Read module type
FE 37
254 55
254 '7'
see table
Reads the module type. See table in section
6.1.13.
Set RS232 port
speed
FE 39 [speed]
254 57 [speed]
254 '9' [speed]
19,200 baud
Sets RS232 speed. See table in section
6.1.14 for values of [speed]
Set Serial Number
FE 34 [byte1][byte2]
254 52 [byte1][byte2]
254 '4' [byte1][byte2]
This is a one-time-use command which
works only on units without factory set serial
numbers.
Read Serial Number
FE 35
254 53
254 '5'
FF FF
Reads the two byte serial number of the
module.
Read Version
Number
FE 36
254 54
254 '6'
Reads the firmware version number of the
module.
Enter flow control
mode
FE 3A [full] [empty]
254 58 [full] [empty]
254 ':' [full] [empty]
off
Sets "full" and "empty" marks for the 80 byte
display buffer. When buffer reaches [full]
display will return 0xFE to host. When buffer
reaches [empty] display will return 0xFF.
Exit flow control
mode
FE 3B
254 59
254 ';'
Turns off flow control.