MagTek JMSR Applet for MagTek User Manual
Page 8
JMSR Applet Programmer’s Guide
4
SetTrack1MskLen(value)
When this function is called by JMSR applet, it receives the length of masked track1
data.
SetTrack2MskLen(value)
When this function is called by JMSR applet, it receives the length of masked track2
data.
SetTrack3MskLen(value)
When this function is called by JMSR applet, it receives the length of masked track3
data.
SetTrk1Encrypted(value)
When this function is called by JMSR applet, it receives track 1 encrypted data.
SetTrk2Encrypted(value)
When this function is called by JMSR applet, it receives track 2 encrypted data.
SetTrk3Encrypted(value)
When this function is called by JMSR applet, it receives track 3 encrypted.
SetTrack1MskData(value)
When this function is called by JMSR applet, it receives track 1 data masked.
SetTrack2MskData(value)
When this function is called by JMSR applet, it receives track 2 data masked.
SetTrack3MskData(value)
When this function is called by JMSR applet, it receives track 3 data masked.
SetMPStatus(value)
When this function is called by JMSR applet, it receives status of MagnePrint data.
SetMPData(value)
When this function is called by JMSR applet, it receives MagnePrint data