Logenable method, Opendevice method, Processcheck method – MagTek Excella API OCX99875557 User Manual
Page 14
![background image](/manuals/413694/14/background.png)
Encrypting SPI IntelliHead
10
LOGENABLE METHOD
Enables or disables logging.
Syntax
Result =MTEXCELLAAPI1.LogEnable (ByVal bEnable As Integer )
Part
Description
bEnable
A value of true enables logging.
OPENDEVICE METHOD
Opens the device with the given device name.
Syntax
Result =MTEXCELLAAPI1.OpenDevice (ByVal lpszDeviceName As String ) as Long
Part
Description
lpszDeviceName
A string that specifies the name of the device.
Data Type
Long
PROCESSCHECK METHOD
Sends a scan check request with the given process options to a device.
Syntax
Result =MTEXCELLAAPI1.ProcessCheck (ByVal lpszDeviceName As String, ByVal
lpszOptions As String, ByRef lpszDocInfo As String, ByRef lplDocInfoSize As Long) as Long
Part
Description
lpszDeviceName
A string that specifies the name of the device.
lpszOptions
A string that specifies all the key/value pairs.
lpszDocInfo
A string containing the information returned from the device. The returned information
contains command status, MICR data, and image information.
lplDocInfoSize
The size of lpszDocInfo.
Data Type
Long