Output control keys – Agilent Technologies 6814B User Manual
Page 36

4 - Front Panel Operation
36
Press this key to access the harmonic menu list
Display
Measurement
current harmonic magnitude
°
I:PHASE:
current harmonic phase
voltage harmonic magnitude
°
V:PHASE:
voltage harmonic phase
neutral current harmonic magnitude
°
N:PHASE:
neutral current harmonic phase
°
CURR:THD
current total % harmonic distortion
°
VOLT:THD
voltage total % harmonic distortion
Output Control Keys
Output control keys control the output functions of the ac source.
Press this key to access the voltage menu list.
Display
Command Function
VOLT
Set immediate rms output voltage (
φ
)
VOLT:T
Set triggered rms output voltage (
φ
)
VOLT:M
Select the voltage mode (
φ
) (FIXED, STEP, PULSE or LIST)
RANGE
Select the voltage range (
φ
) (150 or 300)
SLEW
Set immediate voltage slew rate in volts/second (
φ
)
SLEW:T
Set triggered voltage slew rate in volts/second (
φ
)
SLEW:M
Select the voltage slew mode (
φ
) (FIXED, STEP, PULSE or LIST)
ALC
Select the voltage sense source (INT or EXT)
Press this key to access the current menu list.
Display
Command Function
CURR:LEV
Set immediate rms output current limit
Press this key to access the frequency menu list.
Display
Command Function
FREQ
Set immediate output frequency
FREQ:T
Set triggered output frequency
FREQ:M
Select the frequency mode (FIXED, STEP, PULSE or LIST)
SLEW
Set immediate frequency slew rate in volts/second
SLEW:T
Set triggered frequency slew rate in volts/second
SLEW:M
Select the frequency slew mode (FIXED, STEP, PULSE or LIST)
Notes:
φ
= phase selectable on Agilent 6834B
reading = the returned measurement
index = a numeric value that represents the harmonic number from 0 to 50
char = a character string parameter
and scroll through the command list.
and scroll through the parameter list.
and specify the desired harmonic.
Harmonic
Shift
Voltage
Shift
Current
Freq
q
p
¯
°
pIndex
qIndex