beautypg.com

Specifications – ADC DMPS-10CE User Manual

Page 4

background image

ADCP-50-404 • Issue 2 • November 1998

Page 4
© 1998, ADC Telecommunications, Inc.

Ripple voltage* is held to the following limits:

+5 Vdc, at or below 50 Millivolts, Peak-to-Peak

+12 Vdc, at or below 120 Millivolts, Peak-to-Peak

–12 Vdc, at or below 120 Millivolts, Peak-to-Peak

* Measured with a device having a 50 MHz bandwidth.

4. SPECIFICATIONS

PARAMETER

SPECIFICATION

Input

Voltage

190/240 Vac

Current

2 Amps Maximum (4 Modules)

Frequency

48 to 62 Hz

Fusing (On rear of basic unit)

220 Vac: 4-Amp, Dual, Time Delay

Output Each Module

Voltage

+5 Vdc ± 5%

+12 Vdc ± 10%

–12 Vdc ± 10%

Current

4.5 Amp DC Max. @ +5 V

1.0 Amp DC Max. @ +12 V

0.5 Amp DC Max. @ –12 V

Physical

Chassis

3.5

19 11 inches (8.9 48.3 27.94 cm)

Expansion Module

3.5

3.9 9.22 inches (8.9 9.91 23.5 cm)

Environmental

Operating Temperature

0

to 50 C (32 to 122 F)

Storage Temperature

–40

to +70 C (–40 to 158 F)

Operating Humidity

10 to 80% non-condensing

Storage Humidity

5 to 90% non-condensing

Electromagnetic Compatibility

Meets CISPR22 Class B radiated and conducted emissions.