17

Water Information ____________________

Before You Start

Check Local Codes and Permits

Call your local water company or the proper municipal
authority for information regarding local codes.

Important

It is your responsibility to have all plumbing
connections made by a qualified professional to

ensure that the plumbing installation is adequate and
conforms to local, state, and federal regulations or codes.

It is the installer’s or owner’s responsibility to see that the
necessary or required water, water pressure, pipe size, or
connections are provided. The manufacturer assumes no
responsibility if the fire suppression system is not connected,
installed, or maintained properly.

Installation Requirements

The fire suppression system must be supplied with a minimum
water pipe size of 1/2” and be provided with 40 psi +/- 20 psi
(2.75 bar +/- 1.37 bar) of pressure. For use of optional manual
bypass, a second source with the same piping and pressure
requirements is required.
Flexible 1/2 feeds must be provided to avoid damage to
electric water solenoid valve by vibration.

Important

Flexible supply line/coupling must be used.
Solenoid valve failure due to hard plumbing

connections will void warranty.

Typical Water Supply

!

!

!

!

!

If the rear area of the dryer or the water supply is located in
an area where it will be exposed to cold/freezing
temperatures, provisions must be made to protect these water
lines from freezing.

Warning

If the water in the supply line or water solenoid
valve freezes, the fire suppression system will be

inoperative!!

Important

Appliance is to be connected to the water mains
using a new hose set and the old hose set should

not be reused.

Water Connections

The water connection is made to the 3/4” M.P.T. hex bushing
located at the rear upper midsection of the dryer.

The water solenoid valve has a 3/8” M.P.T. connection
supplied with a 3/4” M.P.T. x 3/8” F.P.T. hex bushing to provide
the minimum 1/2-inch supply (feed) line. Flexible supply line/
coupling must be used in an effort to avoid damaging the
electric water solenoid valve.

Important

Flexible supply line/coupling must be used.
Solenoid valve failure due to hard plumbing

connections will void warranty. It is recommended that a
filter or strainer be installed in the water supply line.