Safety precautions
S
Only have the appliance connected and commissioned by a qualified engineer or by the
afterĆsales service.
S
Comply with the legal requirements and the connection requirements of the electricity and
water supply companies.
S
IEC 600364Ć7Ć701 (DIN VDE 0100 part 701) must be observed when installing the appliance
and/or electrical accessories.
S
AllĆpole isolation with a contact opening of at least 3 mm should be fitted on the installation
side.
S
The flowĆthrough water heater must only be installed in a frostĆfree area.
S
Disassembled appliances must be stored in a frostĆfree area (residual water).
S
The appliance must not be connected if there is a risk that it is frozen.
S
The hotĆwater pipe can become hot. Warn children about this.
S
To avoid potential hazards, repairs must only be carried out by a qualified engineer.
Before installation, disconnect the electric cable from the current and shut off the water
pipe.
S
First connect the water and then the electrical connection.
S
After installation it must not be possible to touch any live parts.
Product description
This instruction manual describes various appliance models.
General
S
The hydraulically controlled flowĆthrough water heater is suitable for either an open
(depressurised) or closed (pressurised) connection.
S
The flowĆthrough water heater continuously heats water while it flows through the appliance.
S
The appliance must not be operated with preheated water, otherwise the overtemperature
protection will be triggered.
DH04101
S
This appliance is connected to the mains by a plug.
DH05101, DH06101 and DH06111
S
These appliances are designed for permanent electrical connection.
DH06111
high level appliance
DH04101, DH05101 and DH06101
under counter appliances