(2) With a meter (either a multimeter or ohmmeter) set on the 200 ohm position,

place the meter leads across:

(a) Terminals 1 and 2...the reading should be approximately 96 ohms +/- 5 ohms.
(b) Terminals 2 and 3...the reading should be approximately 96 ohms +/- 5 ohms

also.

(3) If, after checking the resistance values on the gas valve it is determined that the

ohm readings do not approximate the ohm values listed above (96 ohms
[+/- 5 ohms] for both readings respectively), then, the gas valve must be
replaced.

36E Redundant Gas Valve

4) HSI (Hot Surface Ignition) 24 VAC Redundant Gas Valve

IMPORTANT: The HSI 24 VAC Redundant Gas Valve contain no serviceable parts.

REPLACEMENT COILS ARE NOT AVAILABLE.

IMPORTANT: THERE ARE NO PARTS AVAILABLE FOR FIELD REPAIR. Replace

gas valve only with exact model and/or type number as noted on gas
valve.

a ) The redundant gas valve utilize 24 VAC, which is provided by the HSI module.

(1) To check the resistance value;

(a) Disconnect the terminations at the gas valve from the HSI module.

WARNING: When taking ohm readings, the terminations from the HSI module must be

disconnected/removed, otherwise, the readings obtained will be incorrect
and/or erroneous.